383050 CONSTRUCTION GROUT HIGH PERFORMANCE NON-SHRINK CEMENT GROUT from Red-Darragh

CONSTRUCTION GROUT HIGH PERFORMANCE NON-SHRINK CEMENT GROUT

Red Diamond

383050

Description

Red Diamond™ Non-Shrink Grout is a high-strength, non-metallic, non-shrink cement-based grout engineered for precision, reliability, and performance in demanding commercial construction environments. As part of Darragh Company’s exclusive Red Diamond professional product line, this grout is specially formulated to meet the high standards of commercial concrete contractors—delivering consistent results from damp-pack to flowable applications.

Manufactured to meet ASTM C-1107 Grade A, B & C and U.S. Army Corps of Engineers CRD-C-621 standards, Red Diamond Non-Shrink Grout ensures superior compressive strength, dimensional stability, and lasting performance in base plate, anchor bolt, and machinery grouting applications.

Key Features

  • Exclusive Red Diamond™ Quality: Darragh’s proprietary professional-grade formulation for commercial concrete contractors.
  • Controlled Positive Expansion: Maintains tight contact for maximum bearing and zero shrinkage.
  • High Compressive Strength: Achieves up to 10,200 psi at 28 days for heavy-duty structural support.
  • Non-Metallic & Non-Corrosive: Chloride- and gypsum-free, ideal for long-term durability.
  • Pourable or Pumpable: Easily adaptable from plastic to fluid consistencies for a variety of placements.
  • Freeze/Thaw Resistant: Withstands harsh temperature cycles without cracking or loss of strength.
  • LEED Contributing Product: Can help qualify for LEED credits in sustainable building projects.
  • USDA Accepted: Approved for use in food and beverage facilities.
  • Simple Installation: Just add water—no additional cement, sand, or admixtures required.

Applications

  • Precision grouting of machine bases, column base plates, anchor bolts, and equipment pads
  • Precast and tilt-up wall grouting
  • Bearing plates, bridge seats, and structural columns
  • Void filling and concrete repair under foundations and precast members
  • Deep grouting applications, when extended with 3/8” pea gravel

Placement & Use Guidelines

  • Surface Prep: Remove all debris, oil, and contaminants. Ensure a saturated surface dry (SSD) substrate.
  • Mixing: Always add water first, then grout. Mix 2–3 minutes until uniform; avoid overmixing or excessive water.
  • Placement: Place from one side to prevent air entrapment. Maintain 1” minimum clearance under base plates.
  • Curing: Begin water curing immediately or cover with wet rags; after set, apply an ASTM C-309 curing compound.
  • Temperature Considerations: Follow ACI 305 for hot weather and ACI 306 for cold weather concrete placement.

 

Property Plastic Flowable Fluid
Water / 50 lb 6.3–6.85 pints 6.85–7.75 pints 7.75–8.35 pints
Compressive Strength (ASTM C-109) 4,000 psi (1 day) / 10,200 psi (28 days) 3,100 psi (1 day) / 8,400 psi (28 days) 1,450 psi (1 day) / 8,100 psi (28 days)
Flexural Strength (ASTM C-78) 1,415 psi @ 28 days 1,415 psi @ 28 days 1,415 psi @ 28 days
Tensile Strength (ASTM C-190) 620 psi @ 28 days 620 psi @ 28 days 620 psi @ 28 days
Split Tensile (ASTM C-469) 735 psi @ 28 days 735 psi @ 28 days 735 psi @ 28 days

This download is available in more than one file format. Please select the file format you want to download.

Pending Reviews